CT25M2TX Repair Tips
Search: CT25M2TX
Results 4
Results 4
Make | Model Ch. | Symptom | Problem Solution | Solution | By: |
---|---|---|---|---|---|
Mitsubishi | CT25M2TX | Frame collapse, destruction of AN5521 frame chip at switch on | Replace the AN5521 then replace the 47uF, 35v electrolytic in the power supply. Also check the 330uF, 35v capacitor next to the frame chip for leakage | ||
Mitsubishi | CT25M2TX | OK at sw on then no osg aft 30sec. Aft 5mins blank raster for 10sec on chan change or adj Vol | If freezing field chip IC454 AN5521 works ok - chip faulty | ||
Mitsubishi | CT25M2TX | No E/W control with excess width | Dry joint C558 caused failure of IC5E1 TEA2031A on E/W pcb & L555 s/c turns (should read 80R) Pt no MITS409P749010 | ||
Mitsubishi | CT25M2TX | EXCESSIVE WIDTH WITH BENT VERTICALS | CHECK FOR DRY JOINTS ON C558 WHICH CAUSES IC5E1 AND L555 TO FAULT |