CT25M2TX Repair Tips




Search: CT25M2TX
Results 4
MakeModel Ch.SymptomProblem SolutionSolutionBy:
Mitsubishi CT25M2TX
Frame collapse, destruction of AN5521 frame chip at switch onReplace the AN5521 then replace the 47uF, 35v electrolytic in the power supply. Also check the 330uF, 35v capacitor next to the frame chip for leakage
MitsubishiCT25M2TX
OK at sw on then no osg aft 30sec. Aft 5mins blank raster for 10sec on chan change or adj VolIf freezing field chip IC454 AN5521 works ok - chip faulty
MitsubishiCT25M2TX
No E/W control with excess widthDry joint C558 caused failure of IC5E1 TEA2031A on E/W pcb & L555 s/c turns (should read 80R) Pt no MITS409P749010
MitsubishiCT25M2TX
EXCESSIVE WIDTH WITH BENT VERTICALSCHECK FOR DRY JOINTS ON C558 WHICH CAUSES IC5E1 AND L555 TO FAULT